{"id":789,"date":"2017-07-15T14:11:52","date_gmt":"2017-07-15T14:11:52","guid":{"rendered":"https:\/\/jimkerkhoff.com\/test-roycreekranch\/?p=789"},"modified":"2017-11-14T00:32:27","modified_gmt":"2017-11-14T00:32:27","slug":"solar-powered-rainwater-project-final-assembly","status":"publish","type":"post","link":"https:\/\/jimkerkhoff.com\/test-roycreekranch\/2017\/07\/15\/solar-powered-rainwater-project-final-assembly\/","title":{"rendered":"Solar Powered Rainwater Project &#8211; Final Assembly"},"content":{"rendered":"<p>With all the parts in stock, it was time to assemble the whole Solar Powered Rainwater Project. I cleaned out a space in the garden shed, and added plywood to the wall for attaching the various components. We would be mounting the <a href=\"http:\/\/amzn.to\/2tqB87t\" target=\"_blank\" rel=\"noopener\">inverter\/charge controller<\/a>, <a href=\"http:\/\/amzn.to\/2ul5qgj\" target=\"_blank\" rel=\"noopener\">solar panel combiner\/breakers<\/a>, <a href=\"http:\/\/amzn.to\/2t1BGRF\" target=\"_blank\" rel=\"noopener\">A\/C transfer switch<\/a> and related wiring.<\/p>\n<h3>Mount up!<\/h3>\n<div id=\"attachment_794\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Everything-mounted.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-794\" data-attachment-id=\"794\" data-permalink=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/2017\/07\/15\/solar-powered-rainwater-project-final-assembly\/everything-mounted\/\" data-orig-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Everything-mounted.jpg\" data-orig-size=\"1280,960\" data-comments-opened=\"0\" data-image-meta=\"{&quot;aperture&quot;:&quot;2.2&quot;,&quot;credit&quot;:&quot;Jim Kerkhoff&quot;,&quot;camera&quot;:&quot;iPhone 6&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1499091982&quot;,&quot;copyright&quot;:&quot;Jim Kerkhoff \\u00a9 2017 http:\\\/\\\/creativecommons.org\\\/licenses\\\/by-nc-sa\\\/4.0\\\/&quot;,&quot;focal_length&quot;:&quot;4.15&quot;,&quot;iso&quot;:&quot;125&quot;,&quot;shutter_speed&quot;:&quot;0.033333333333333&quot;,&quot;title&quot;:&quot;Everything mounted!&quot;,&quot;orientation&quot;:&quot;1&quot;}\" data-image-title=\"Everything mounted!\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;Everything mounted!&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Everything-mounted-300x225.jpg\" data-large-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Everything-mounted-1024x768.jpg\" class=\"size-medium wp-image-794\" src=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Everything-mounted-300x225.jpg\" alt=\"photo of Everything mounted!\" width=\"300\" height=\"225\" srcset=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Everything-mounted-300x225.jpg 300w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Everything-mounted-1024x768.jpg 1024w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Everything-mounted-400x300.jpg 400w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Everything-mounted.jpg 1280w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-794\" class=\"wp-caption-text\">Everything mounted!<\/p><\/div>\n<p>The <a href=\"http:\/\/amzn.to\/2tqB87t\" target=\"_blank\" rel=\"noopener\">inverter\/charge controller<\/a> was first. At about 100 pounds, it was too much to handle alone, so my friend Norman helped. The good news was that the inverter mounting holes were 15 1\/2-inches apart &#8212; perfect for mounting to a wall with 16-inch-on-center studs. That done, we mounted the solar combiner box and transfer switch.<\/p>\n<h3>Connecting the Solar Panels<\/h3>\n<div id=\"attachment_793\" style=\"width: 235px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Panel-combiner-wiring.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-793\" data-attachment-id=\"793\" data-permalink=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/2017\/07\/15\/solar-powered-rainwater-project-final-assembly\/panel-combiner-wiring\/\" data-orig-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Panel-combiner-wiring.jpg\" data-orig-size=\"960,1280\" data-comments-opened=\"0\" data-image-meta=\"{&quot;aperture&quot;:&quot;2.2&quot;,&quot;credit&quot;:&quot;Jim Kerkhoff&quot;,&quot;camera&quot;:&quot;iPhone 6&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1499419150&quot;,&quot;copyright&quot;:&quot;Jim Kerkhoff \\u00a9 2017 http:\\\/\\\/creativecommons.org\\\/licenses\\\/by-nc-sa\\\/4.0\\\/&quot;,&quot;focal_length&quot;:&quot;4.15&quot;,&quot;iso&quot;:&quot;250&quot;,&quot;shutter_speed&quot;:&quot;0.05&quot;,&quot;title&quot;:&quot;Panel combiner wiring&quot;,&quot;orientation&quot;:&quot;1&quot;}\" data-image-title=\"Panel combiner wiring\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;Panel combiner wiring&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Panel-combiner-wiring-225x300.jpg\" data-large-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Panel-combiner-wiring-768x1024.jpg\" class=\"size-medium wp-image-793\" src=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Panel-combiner-wiring-225x300.jpg\" alt=\"photo of the Panel combiner wiring\" width=\"225\" height=\"300\" srcset=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Panel-combiner-wiring-225x300.jpg 225w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Panel-combiner-wiring-768x1024.jpg 768w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Panel-combiner-wiring.jpg 960w\" sizes=\"auto, (max-width: 225px) 100vw, 225px\" \/><\/a><p id=\"caption-attachment-793\" class=\"wp-caption-text\">Panel combiner wiring<\/p><\/div>\n<p>Wiring the <a href=\"http:\/\/amzn.to\/2tUxK85\" target=\"_blank\" rel=\"noopener\">solar panels<\/a> was next. The two, 24-volt panels are connected in series to produce 48 volts, so only one 2-conductor wire was needed. I used 12-gauge landscape wire because it is relatively inexpensive and is intended for outdoor service. Assembling the <a href=\"http:\/\/amzn.to\/2upIigo\" target=\"_blank\" rel=\"noopener\">DC breaker<\/a> into the <a href=\"http:\/\/amzn.to\/2ul5qgj\" target=\"_blank\" rel=\"noopener\">solar combiner box<\/a> was simple, and the box has space for two more breakers to connect additional 48-volt panel strings. Another pair of heavy wires connects the combiner output to the DC input on the inverter\/charge controller.<\/p>\n<h3>Wiring the A\/C Mains<\/h3>\n<div id=\"attachment_792\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/A-C-and-PV-panels-connected.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-792\" data-attachment-id=\"792\" data-permalink=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/2017\/07\/15\/solar-powered-rainwater-project-final-assembly\/ac-and-pv-panels-connected\/\" data-orig-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/A-C-and-PV-panels-connected.jpg\" data-orig-size=\"1280,960\" data-comments-opened=\"0\" data-image-meta=\"{&quot;aperture&quot;:&quot;2.2&quot;,&quot;credit&quot;:&quot;Jim Kerkhoff&quot;,&quot;camera&quot;:&quot;iPhone 6&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1499679644&quot;,&quot;copyright&quot;:&quot;Jim Kerkhoff \\u00a9 2017 http:\\\/\\\/creativecommons.org\\\/licenses\\\/by-nc-sa\\\/4.0\\\/&quot;,&quot;focal_length&quot;:&quot;4.15&quot;,&quot;iso&quot;:&quot;250&quot;,&quot;shutter_speed&quot;:&quot;0.041666666666667&quot;,&quot;title&quot;:&quot;A\\\/C and PV panels connected&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"A\/C and PV panels connected\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;A\/C and PV panels connected&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/A-C-and-PV-panels-connected-300x225.jpg\" data-large-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/A-C-and-PV-panels-connected-1024x768.jpg\" class=\"size-medium wp-image-792\" src=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/A-C-and-PV-panels-connected-300x225.jpg\" alt=\"photo of the A\/C and PV panels connected\" width=\"300\" height=\"225\" srcset=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/A-C-and-PV-panels-connected-300x225.jpg 300w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/A-C-and-PV-panels-connected-1024x768.jpg 1024w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/A-C-and-PV-panels-connected-400x300.jpg 400w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/A-C-and-PV-panels-connected.jpg 1280w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-792\" class=\"wp-caption-text\">A\/C and PV panels connected<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>The next connections to the inverter were for 240 VAC power. Commercial power is connected to the input, and the output connects to the transfer switch in my system. This way, we can select either solar generator or commercial power for each load; water well, greenhouse (with the rainwater system), lighting and outlets. It&#8217;s an added complication, but otherwise I would have to power everything with either solar or commercial power at the same time.<\/p>\n<h3>The A\/C Transfer Switch<\/h3>\n<div id=\"attachment_795\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-wired.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-795\" data-attachment-id=\"795\" data-permalink=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/2017\/07\/15\/solar-powered-rainwater-project-final-assembly\/transfer-switch-wired\/\" data-orig-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-wired.jpg\" data-orig-size=\"1280,960\" data-comments-opened=\"0\" data-image-meta=\"{&quot;aperture&quot;:&quot;2.2&quot;,&quot;credit&quot;:&quot;Jim Kerkhoff&quot;,&quot;camera&quot;:&quot;iPhone 6&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1499679610&quot;,&quot;copyright&quot;:&quot;Jim Kerkhoff \\u00a9 2017 http:\\\/\\\/creativecommons.org\\\/licenses\\\/by-nc-sa\\\/4.0\\\/&quot;,&quot;focal_length&quot;:&quot;4.15&quot;,&quot;iso&quot;:&quot;100&quot;,&quot;shutter_speed&quot;:&quot;0.033333333333333&quot;,&quot;title&quot;:&quot;Transfer switch wired&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Transfer switch wired\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;Transfer switch wired&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-wired-300x225.jpg\" data-large-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-wired-1024x768.jpg\" class=\"size-medium wp-image-795\" src=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-wired-300x225.jpg\" alt=\"photo of the Transfer switch wired\" width=\"300\" height=\"225\" srcset=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-wired-300x225.jpg 300w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-wired-1024x768.jpg 1024w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-wired-400x300.jpg 400w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-wired.jpg 1280w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-795\" class=\"wp-caption-text\">Transfer switch wired<\/p><\/div>\n<p>Now, the <a href=\"http:\/\/amzn.to\/2t1BGRF\" target=\"_blank\" rel=\"noopener\">transfer switch<\/a>. These are commonly used with generators so that each load can be selectively powered by either the generator or commercial power. It has the added advantage of preventing generated power from connecting to the commercial power grid. This is very important because linemen working on the commercial grid during a power outage are not expecting supposedly &#8220;dead&#8221; power lines to have power, and might be injured. This keeps everyone safe.<\/p>\n<h3>Configuring the Inverter and Connecting the Batteries<\/h3>\n<p>After mounting the <a href=\"http:\/\/amzn.to\/2tqC5fY\" target=\"_blank\" rel=\"noopener\">200-amp DC breaker <\/a>and <a href=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/2017\/07\/11\/solar-powered-rainwater-project-batteries\/\">connecting the batteries<\/a>, we were ready for testing. I configured the inverter\/charge controller according to the manual and DIP switches were set for Deep-cycle battery, utility power mode, 60 Hz line frequency and battery priority. Even though I had checked each connection made over the last few days, there was still a little thrill of anxiety &#8212; did I get it all right? Also, would the inverter be stout enough to power the well pump? If it worked, I could be sure that the rainwater system would work since it uses only half as much power.<\/p>\n<h3>But will it work?<\/h3>\n<div id=\"attachment_804\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Inverter-control-panel.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-804\" data-attachment-id=\"804\" data-permalink=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/2017\/07\/15\/solar-powered-rainwater-project-final-assembly\/inverter-control-panel\/\" data-orig-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Inverter-control-panel.jpg\" data-orig-size=\"1280,960\" data-comments-opened=\"0\" data-image-meta=\"{&quot;aperture&quot;:&quot;2.2&quot;,&quot;credit&quot;:&quot;Jim Kerkhoff&quot;,&quot;camera&quot;:&quot;iPhone 6&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1500058857&quot;,&quot;copyright&quot;:&quot;Jim Kerkhoff \\u00a9 2017 http:\\\/\\\/creativecommons.org\\\/licenses\\\/by-nc-sa\\\/4.0\\\/&quot;,&quot;focal_length&quot;:&quot;4.15&quot;,&quot;iso&quot;:&quot;250&quot;,&quot;shutter_speed&quot;:&quot;0.066666666666667&quot;,&quot;title&quot;:&quot;Inverter control panel&quot;,&quot;orientation&quot;:&quot;1&quot;}\" data-image-title=\"Inverter control panel\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;Inverter control panel&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Inverter-control-panel-300x225.jpg\" data-large-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Inverter-control-panel-1024x768.jpg\" class=\"size-medium wp-image-804\" src=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Inverter-control-panel-300x225.jpg\" alt=\"photo of the Inverter control panel\" width=\"300\" height=\"225\" srcset=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Inverter-control-panel-300x225.jpg 300w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Inverter-control-panel-1024x768.jpg 1024w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Inverter-control-panel-400x300.jpg 400w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Inverter-control-panel.jpg 1280w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-804\" class=\"wp-caption-text\">Inverter control panel<\/p><\/div>\n<p>Time to power the inverter. The lights on the front flashed with their self-test and the &#8220;inverter&#8221; LED stayed lit. Everything was powered. As I threw one of the transfer switches for the garden shed lights to the &#8220;GEN&#8221; position, they didn&#8217;t even blink. They were running on the inverter. Now, the outlets that power the ultraviolet filter. Again, not even a blink &#8212; still running.\u00a0Moment of truth time. A sprinkler was running in the garden and soon it would start the well pump. I flipped the switches for the well pump to &#8220;GEN&#8221; and waited. The pressure switch clicked on, and the well pump started humming. The inverter had started a 1 1\/2 horsepower well pump. Success. We would be celebrating tonight!<\/p>\n<h3>Measuring the results<\/h3>\n<div id=\"attachment_803\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Digital-power-meter.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-803\" data-attachment-id=\"803\" data-permalink=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/2017\/07\/15\/solar-powered-rainwater-project-final-assembly\/digital-power-meter\/\" data-orig-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Digital-power-meter.jpg\" data-orig-size=\"1280,960\" data-comments-opened=\"0\" data-image-meta=\"{&quot;aperture&quot;:&quot;2.2&quot;,&quot;credit&quot;:&quot;Jim Kerkhoff&quot;,&quot;camera&quot;:&quot;iPhone 6&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1500058881&quot;,&quot;copyright&quot;:&quot;Jim Kerkhoff \\u00a9 2017 http:\\\/\\\/creativecommons.org\\\/licenses\\\/by-nc-sa\\\/4.0\\\/&quot;,&quot;focal_length&quot;:&quot;4.15&quot;,&quot;iso&quot;:&quot;250&quot;,&quot;shutter_speed&quot;:&quot;0.058823529411765&quot;,&quot;title&quot;:&quot;Digital power meter&quot;,&quot;orientation&quot;:&quot;1&quot;}\" data-image-title=\"Digital power meter\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;Digital power meter&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Digital-power-meter-300x225.jpg\" data-large-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Digital-power-meter-1024x768.jpg\" class=\"size-medium wp-image-803\" src=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Digital-power-meter-300x225.jpg\" alt=\"photo of a Digital power meter\" width=\"300\" height=\"225\" srcset=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Digital-power-meter-300x225.jpg 300w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Digital-power-meter-1024x768.jpg 1024w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Digital-power-meter-400x300.jpg 400w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Digital-power-meter.jpg 1280w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-803\" class=\"wp-caption-text\">Digital power meter<\/p><\/div>\n<p>Finally, I installed the last element of the system &#8212; a <a href=\"http:\/\/amzn.to\/2ukS9o3\" target=\"_blank\" rel=\"noopener\">digital meter<\/a> that measures voltage, current and wattage drawn from the battery bank. With it, I can see the battery voltage change as sunlight and power loads change &#8212; confirming that the solar panels and MPPT charge controller are working as expected. What I know already is that we&#8217;ll need two more panels. My <a href=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/2017\/03\/21\/solar-powered-rainwater-project-panels-batteries-and-inverters-oh-my\/\">calculations predicted this<\/a>, but I didn&#8217;t realize that the inverter draws a constant 70 watts when powered. That, combined with the \u00a0power used by the ultraviolet filter (about 30 watts) mean that most of the power generated by two panels in 24 hours is used each day. 100 watts times 24 hours is 2400 watt\/hours used. 500 watts of solar panel times an insolation of 5 is about 2500 watt\/hours of power generated. Most of the power generated is being used by small, but constant power drains that cannot be avoided. Still, we have a complete, working system to learn on. Very exciting! <a href=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/2017\/11\/14\/more-panels\/\">Now &#8212; about those panels . . .<\/a><\/p>\n<div id=\"attachment_801\" style=\"width: 950px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-with-power-meter.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-801\" data-attachment-id=\"801\" data-permalink=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/2017\/07\/15\/solar-powered-rainwater-project-final-assembly\/transfer-switch-with-power-meter\/\" data-orig-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-with-power-meter.jpg\" data-orig-size=\"1280,960\" data-comments-opened=\"0\" data-image-meta=\"{&quot;aperture&quot;:&quot;2.2&quot;,&quot;credit&quot;:&quot;Jim Kerkhoff&quot;,&quot;camera&quot;:&quot;iPhone 6&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1499970424&quot;,&quot;copyright&quot;:&quot;Jim Kerkhoff \\u00a9 2017 http:\\\/\\\/creativecommons.org\\\/licenses\\\/by-nc-sa\\\/4.0\\\/&quot;,&quot;focal_length&quot;:&quot;4.15&quot;,&quot;iso&quot;:&quot;250&quot;,&quot;shutter_speed&quot;:&quot;0.033333333333333&quot;,&quot;title&quot;:&quot;Transfer switch with power meter&quot;,&quot;orientation&quot;:&quot;1&quot;}\" data-image-title=\"Transfer switch with power meter\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;Transfer switch with power meter&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-with-power-meter-300x225.jpg\" data-large-file=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-with-power-meter-1024x768.jpg\" class=\"size-large wp-image-801\" src=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-with-power-meter-1024x768.jpg\" alt=\"photo of the Transfer switch with power meter\" width=\"940\" height=\"705\" srcset=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-with-power-meter-1024x768.jpg 1024w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-with-power-meter-300x225.jpg 300w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-with-power-meter-400x300.jpg 400w, https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Transfer-switch-with-power-meter.jpg 1280w\" sizes=\"auto, (max-width: 940px) 100vw, 940px\" \/><\/a><p id=\"caption-attachment-801\" class=\"wp-caption-text\">Transfer switch with power meter<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>With all the parts in stock, it was time to assemble the whole Solar Powered Rainwater Project. I cleaned out a space in the garden shed, and added plywood to the wall for attaching the various components. We would be mounting the inverter\/charge controller, solar panel combiner\/breakers, A\/C transfer switch and related wiring.<\/p>\n <a class=\"more-link\" href=\"https:\/\/jimkerkhoff.com\/test-roycreekranch\/2017\/07\/15\/solar-powered-rainwater-project-final-assembly\/\"><span class=\"more-msg\">Continue reading &rarr;<\/span><\/a>","protected":false},"author":1,"featured_media":796,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2}},"categories":[44,9,65,5,7,189],"tags":[190,242,239,191,192,193,194,23,195,230,243,196,26,24,197,198,211,209,210,208,199,200,207,201,241,202,100,203,204,240,19,206,205,212],"class_list":["post-789","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-central-texas","category-greenhouse","category-maker","category-projects","category-rainwater","category-solar","tag-amateur","tag-ampere-hours","tag-battery-bank-capacity","tag-build","tag-charge","tag-controller","tag-deep-cycle","tag-diy","tag-equipment","tag-grid-assist","tag-grid-tie","tag-ham-radio","tag-how-to","tag-howto","tag-interstate","tag-inverter","tag-kill-a-watt","tag-kilowatt","tag-kilowatt-hours","tag-kwh","tag-marine","tag-mppt","tag-off-grid","tag-panel","tag-panel-wattage","tag-pwm","tag-rainwater","tag-renogy","tag-solar","tag-solar-panel-wattage","tag-storage","tag-teardrop","tag-trailer","tag-wb0mmc"],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-content\/uploads\/2017\/07\/Fully-assembled.jpg","jetpack_sharing_enabled":true,"jetpack-related-posts":[],"_links":{"self":[{"href":"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-json\/wp\/v2\/posts\/789","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-json\/wp\/v2\/comments?post=789"}],"version-history":[{"count":12,"href":"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-json\/wp\/v2\/posts\/789\/revisions"}],"predecessor-version":[{"id":1015,"href":"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-json\/wp\/v2\/posts\/789\/revisions\/1015"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-json\/wp\/v2\/media\/796"}],"wp:attachment":[{"href":"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-json\/wp\/v2\/media?parent=789"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-json\/wp\/v2\/categories?post=789"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/jimkerkhoff.com\/test-roycreekranch\/wp-json\/wp\/v2\/tags?post=789"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}